Daily Heat & Cool

Seasonal maintenance calendar for heating and cooling

Twelve short checklists that put each job in the month where it prevents the most trouble.

One short list for every month.

Short answer. Four dates carry most of the value: test the furnace in September, change the humidifier water panel in October, rinse the outdoor coil and test the air conditioner in May, and check the filter on the first of every month. The rest of the year is small jobs that take a few minutes each.

Month by month

The calendar assumes a climate with about seven months of heating, three of cooling, and a short spring and autumn with the windows open. Shift it a few weeks either way for your own first and last frost.

January Deep winter

  • After each snowfall, clear the furnace intake and exhaust pipes and the gas meter.
  • Check the filter. The furnace is running its longest hours of the year.
  • Lower the humidifier setting during cold snaps if the windows sweat.
  • Test every carbon monoxide and smoke alarm.

February Late winter

  • Check the furnace condensate trap, tube and pump for sludge or kinks.
  • Look along the eaves for ice dams, a sign of heat leaking into the attic.
  • Replace the filter if it has been in since autumn.
  • Note any room that has been cold all winter, to raise at the next service visit.

March Thaw

  • Lift the sump pump float or pour in a bucket of water to prove the pump runs.
  • Check the basement for damp patches as the ground thaws.
  • Turn the humidifier down as outdoor temperatures climb.
  • Book the spring air conditioner check for April or May.

April Last frosts

  • Turn the humidifier off, close its water valve and close the bypass damper.
  • Take the cover or board off the outdoor unit and clear winter debris.
  • Fit a new filter ahead of the cooling season.
  • Wash window screens and check they close tight.

May Windows open

  • With the power off, rinse the outdoor coil gently with a garden hose until the water runs clear.
  • Run the air conditioner for 20 minutes on a mild day and check for cold air and a dripping drain.
  • Pour a cup of water into the condensate drain to prove it flows.
  • Start the basement dehumidifier and set it to 45 to 50%.

June First heat

  • Switch the thermostat schedule to its cooling setpoints.
  • Keep grass clippings and cottonwood fluff off the outdoor coil.
  • Check that the large insulated refrigerant line is cold and sweating when the unit runs.
  • Clean bath fan grilles so they clear shower moisture.

July Peak cooling

  • Check the filter. A clogged one is the usual start of a frozen coil.
  • Look at the drain pan under the indoor coil for standing water.
  • Close blinds on sunny windows through the afternoon.
  • Empty or check the dehumidifier drain weekly.

August Humid weeks

  • Watch the hygrometer. Above 60% indoors, lengthen AC run times or add dehumidification.
  • Keep basement windows closed on muggy days.
  • Trim plants to leave two feet of space around the outdoor unit.
  • Book the furnace check for September.

September Windows open

  • Turn the heat on for 15 minutes. A brief dusty smell is normal; a furnace that will not start is better found now.
  • Fit a new filter for the heating season.
  • Replace carbon monoxide alarm batteries and check the replace-by dates.
  • Check vent pipes outside for nests and the flue for rust.

October First frosts

  • Fit a new humidifier water panel, open the water valve and the bypass damper.
  • Switch the thermostat schedule to its heating setpoints.
  • Seal obvious drafts: weatherstrip doors, caulk gaps at window trim.
  • Clean the gutters after the leaves fall so meltwater drains away from the foundation.

November Heating season

  • Move furniture and rugs off supply registers and return grilles.
  • Rinse the outdoor unit one last time and leave it uncovered or with a top cover only.
  • Check the filter after the first full month of heating.
  • Put away the dehumidifier once the basement holds under 50% on its own.

December Short days

  • Test the alarms before the house fills with guests.
  • Keep the furnace vent pipes clear of drifting snow and icicles.
  • Set the humidity lower before a cold snap, not after the windows fog.
  • Leave heat on and cabinet doors open under sinks if you travel.

Every month, whatever the season

  • Look at the filter. A 1-inch filter usually lasts one to three months, a 4-inch one six to twelve. Dust from building work, pets and a fan left running all shorten that. The filter guide explains the ratings.
  • Press the test button on each smoke and carbon monoxide alarm.
  • Listen. A new rattle, squeal or hum is the cheapest warning the equipment gives. Note when it happens in the cycle.
  • Glance at the hygrometer. Between 30% and 50% is the range to hold across the year.

When to book professional maintenance

One heating check and one cooling check a year is the usual advice, and timing is most of the value. Book the furnace for September or early October and the air conditioner for April or May. Those are the quiet weeks, so the visit is unhurried and any part that needs ordering arrives before the weather turns.

Autumn furnace visit should includeSpring cooling visit should include
Combustion analysis and a carbon monoxide readingRefrigerant pressures, superheat and subcooling
Inspection of the heat exchanger, burners and igniterCapacitor value and motor current
Flame sensor cleaned, gas pressure checkedContactor and wiring inspected
Condensate trap and drain flushedIndoor coil and drain pan checked, drain flushed
Temperature rise and static pressure measuredTemperature drop across the coil measured
Vent pipes and safety switches checkedOutdoor coil cleaned

A visit that produces written readings is worth more than one that produces a sticker. Keep the sheets; a number that drifts from one year to the next is how a failing part gets caught early.

The daily schedule through the year

The thermostat's four daily periods need adjusting twice a year, not just switching from heat to cool.

PeriodFurnace seasonAC season
Wake68°F, starting 30 to 60 minutes before you get up78°F
Leave60 to 62°F82 to 85°F
Return68°F78°F, starting before the hottest part of the afternoon
Sleep60 to 65°F76 to 78°F

These are starting points to adjust for comfort. Two cautions. With a heat pump, keep winter setbacks to a few degrees so the backup heat is not called on to recover. And in very cold snaps, a deep setback in a house with plumbing in outside walls is a risk to the pipes; hold the house steadier until the cold breaks.

If the equipment does not keep to the schedule, the troubleshooting guides start with the checks you can do yourself: furnace and air conditioner. If you are not sure which trade a problem belongs to, see who to call for what.