AC troubleshooting, from warm air to a frozen coil
The checks worth making before a service visit, what each symptom points to, and the parts of a central air conditioner that are not safe to work on yourself.
AC season is short and intense: June to August, with test runs in May.
Short answer. When a central air conditioner stops cooling, check four things in this order: the thermostat is set to cool, the filter is clean, both breakers are on, and the outdoor unit is actually running with a clear coil. Those account for a large share of no-cooling visits. Ice on the pipes, a humming outdoor unit or a breaker that trips twice are the points to stop and bring in a technician.
- Outdoor unit: compressor, fan and the coil that sheds heat outside
- Refrigerant lines: the large insulated one should feel cold and sweat
- Indoor coil, sitting on the furnace, where the air is cooled and dried
- Condensate drain carrying that water to a floor drain or pump
- Filter slot on the return side of the furnace
- Supply duct to the rooms; the furnace blower moves the air
Not cooling
- Thermostat set to cool, fan on auto, setpoint below the room temperature.
- Filter. A clogged filter is the most common single cause of weak cooling and of a frozen coil.
- Two breakers. The furnace or air handler has one and the outdoor unit has its own two-pole breaker. Check the pull-out disconnect on the wall beside the outdoor unit as well.
- Outdoor unit. The fan on top should spin and the air above it should feel warmer than the day. Clear grass clippings and cottonwood fluff from the fins and keep two feet of open space around it.
- Registers. Open them all. Closing registers in unused rooms raises duct pressure and cuts airflow across the coil.
If the indoor blower runs and air comes out of the registers at room temperature while the outdoor unit sits silent, the fault is outdoors or in the low-voltage wire that tells it to start. If both run and the large insulated pipe at the outdoor unit is not cold, the system is likely low on refrigerant or the compressor is not pumping.
Frozen coil
Ice on the copper lines or on the coil above the furnace means the coil has dropped below freezing. There are two causes: too little air crossing it, or too little refrigerant in it.
- Turn cooling off and set the fan to on. Let the blower thaw the coil. This takes anywhere from an hour to most of a day. Do not chip at the ice.
- Fix the airflow. Fit a new filter, open every register and make sure no return grille is covered by furniture.
- Restart and watch. If it cools normally for days, airflow was the problem. If it ices again with a clean filter, the charge is low or the coil itself is dirty, and that is a technician's visit.
Running an iced system risks sending liquid refrigerant back to the compressor, which is the most expensive part in the outdoor unit.
Short cycling
An air conditioner that runs for three or four minutes, stops, and starts again shortly after is short cycling. It cools poorly, dries the air badly and wears the compressor. The usual causes:
- A coil that is starting to freeze, for the reasons above.
- A dirty outdoor coil, which drives pressure high enough to trip a safety switch.
- A thermostat in a draft, in direct sun or above a supply register.
- An oversized unit. It satisfies the thermostat before it has removed much moisture, so the house feels cool and clammy. This cannot be repaired, only corrected at replacement with a proper load calculation. A dehumidifier helps in the meantime.
Water at the furnace in summer
The indoor coil pulls gallons of water out of humid air on a muggy day. It drips into a pan and leaves through a plastic drain line. When algae and dust plug that line the pan overflows, and the water appears at the base of the furnace.
- Turn cooling off so no more water is made.
- Find where the drain line ends, at a floor drain or a small pump, and pull the clog out with a wet/dry vacuum held on the end of the pipe for a minute.
- If there is a condensate pump, check it is plugged in and that its float moves freely.
- Some systems have a float switch in the drain that shuts the cooling off when water backs up. A dead AC and a full drain pan go together.
Water in winter beside a high-efficiency furnace is a different drain; see furnace condensate.
Tripped breaker
Reset a tripped AC breaker once. If it trips again, leave it off. A breaker that will not hold is reporting a real fault, and each reset pushes a large current through a compressor or wire that may already be damaged.
Common reasons are a compressor struggling to start against a weak capacitor, a condenser fan motor that has seized, a wire rubbed through to bare metal, or a very dirty outdoor coil making the compressor draw more current than it should.
Capacitor and contactor symptoms
These two inexpensive parts in the outdoor unit cause a large share of midsummer failures.
| Part | What it does | Signs it is failing |
|---|---|---|
| Run capacitor | Gives the compressor and fan motors the boost they need to start and run | Outdoor unit hums but the fan does not turn; fan runs but the air above it is not warm; unit starts then trips the breaker; the top of the capacitor is domed or leaking |
| Contactor | A switch that connects 240 volts to the outdoor unit when the thermostat calls | Loud buzzing or chattering; outdoor unit never starts although the thermostat is calling; outdoor unit keeps running after the indoor blower stops |
Recognizing these is useful. Replacing them yourself is not recommended: the cabinet carries 240 volts, and a capacitor holds a charge after the power is off.
What a technician will check
- Temperature drop across the coil. Supply air is typically somewhere around 16 to 22°F cooler than return air on a healthy system.
- Refrigerant pressures, superheat and subcooling, which show whether the charge is correct. Refrigerant is not used up. A low charge means a leak, and topping up without finding it buys a season at best.
- Capacitor value and motor current against the figures on the nameplates.
- Contactor contacts, wiring and the low-voltage circuit.
- Airflow and static pressure in the ducts, and the condition of the indoor coil and blower wheel.
- The condensate drain and any safety switch on it.
Only a technician with EPA Section 608 certification may add or recover refrigerant. Refrigerants cannot be mixed: an existing system must be serviced with the type on its nameplate, usually R-410A, or R-22 on equipment from before 2010. New systems use R-454B or R-32.
Repair or replace?
Capacitors, contactors, fan motors and drain repairs are worth doing at any age. Lean toward replacement when the compressor has failed out of warranty, when the indoor coil is leaking on a system past ten years or so, when the unit still uses R-22, or when it has always short cycled because it is too large. The installation guide has the full comparison, and a May coil rinse from the maintenance calendar prevents a good number of these visits.