Furnace troubleshooting, from no heat to error codes

What to check when a gas furnace will not heat, how to tell a flame sensor from an igniter or pressure switch fault, and where to stop for safety.

Furnace season runs from October to April.

Short answer. A gas furnace that will not heat is usually stopped by something outside the burner: a thermostat setting, a tripped switch, a clogged filter, a blocked vent pipe or a full condensate drain. Check those five first. If the furnace still fails, watch which step of its start-up it reaches, because that tells you (and the technician) which part to suspect.

No heat: seven checks before you book a visit

  • Thermostat. Set to heat, with the setpoint above room temperature. Replace the batteries if the screen is dim or blank.
  • Furnace switch. It looks like a light switch on or near the furnace and is often turned off by accident.
  • Breaker. Reset it once. If it trips again, leave it off.
  • Blower door. A door that is not fully seated holds open a safety switch and the furnace stays dead.
  • Filter. Pull it out and hold it to a light. If you cannot see light through it, replace it.
  • Vent pipes. A furnace rated 90% AFUE or higher breathes through plastic pipes on an outside wall. Clear snow, ice, leaves and nests from both.
  • Gas supply. The handle on the furnace's gas shutoff should run in line with the pipe. If the stove or water heater has no gas either, the problem is upstream of the furnace.

After a few failed tries most furnaces lock themselves out. Turning the furnace switch off for 30 seconds and back on clears the lockout and lets you watch one fresh start.

Watch the start-up sequence

Every modern gas furnace starts in the same order. Stand where you can hear it and see the burner area, ask for heat at the thermostat, and note where it stops.

  1. The inducer fan starts. A small fan clears the heat exchanger and begins pulling air through the vent. Nothing at all happening points to power, the thermostat or the control board.
  2. The pressure switch closes. It confirms the vent is drawing. An inducer that runs and runs with nothing following usually means this switch has not closed.
  3. The igniter heats. A hot surface igniter glows orange for several seconds. Some furnaces use a spark you can hear ticking.
  4. The gas valve opens and the burners light. You hear a click and a soft whoosh. Flames should be steady and blue.
  5. The flame sensor proves the flame. If it cannot, the gas shuts off within a few seconds.
  6. The blower starts. After a short delay warm air reaches the registers.

What each symptom points to

What you seeLikely causeWhose job
Burners light, then go out after a few seconds, several times in a rowDirty flame sensorHomeowner can clean it; see below
Inducer runs, no glow, no flameFailed igniter, or pressure switch not closingTechnician, after you check the vent and drain
Igniter glows, no flameGas supply, gas valve or control boardTechnician
Heats for a few minutes, burners shut off, blower keeps runningHigh limit switch tripping from low airflowReplace the filter and open registers first
Starts and stops every few minutes all dayLimit trips, thermostat placement or an oversized furnaceFilter first, then technician
Water on the floor beside a high-efficiency furnaceBlocked condensate trap, drain or pumpHomeowner can often clear it

Flame sensor

The flame sensor is a thin metal rod that sits in the flame of the last burner. Combustion leaves a film on it over a few winters, and the control board stops recognizing the flame. The symptom is distinctive: the burners light normally, burn for three to five seconds and go out, and the furnace tries again. Cleaning it is a ten-minute job. Switch the furnace off at its switch, remove the single screw holding the sensor, slide it out, wipe the rod with a clean dry cloth or rub it lightly with fine steel wool, and put it back. Do not touch the igniter, which is fragile, or anything connected to the gas line.

Igniter

Hot surface igniters crack with age. A furnace with a dead igniter runs its inducer, waits, and never glows. An igniter is a furnace-specific part and oil from fingers shortens the life of a new one, so most owners leave this replacement to a technician. It is one of the quicker repairs.

Pressure switch

The pressure switch is a safety device, and an open one is usually telling the truth. The common causes are a vent or intake pipe blocked by snow or ice, a condensate trap full of sludge, a cracked or water-filled rubber hose to the switch, or a weak inducer. Clear the pipes outside and check the drain. Never jumper a pressure switch to make the furnace run; it exists to stop exhaust backing up into the house.

Clogged filter and limit trips

If too little air crosses the heat exchanger it overheats, and the high limit switch shuts the burners off while the blower cools things down. Then the cycle repeats. A clogged filter is the usual cause, followed by closed or blocked registers and a dirty blower wheel. Repeated limit trips are hard on the heat exchanger, so do not leave a short-cycling furnace for the end of the season. A filter that is too restrictive for the ductwork can do the same thing; the filter guide explains how to choose one.

Condensate on 90%+ furnaces

A condensing furnace wrings so much heat out of its exhaust that water condenses inside it, often several gallons on a cold day. That water runs through a trap to a floor drain or a small pump. When the trap clogs or the pump fails, water backs up, the pressure switch opens and the furnace stops. Look for a full trap, a kinked tube, a pump with a full reservoir that is not running, or a drain line that passes through an unheated space and has frozen.

Read the error-code light

The control board has a small LED that blinks a fault code. Look for it through the sight glass in the lower door before you remove the door or cut the power, because many boards forget the code when they lose power. Count the flashes (often a pattern of short and long), then match them to the chart printed on the inside of the door or in the manual. Codes are specific to each make, so write down the pattern rather than guessing. "Pressure switch stuck open" or "limit circuit open" narrows the search to one of the sections above.

Carbon monoxide safety

If a carbon monoxide alarm sounds, get everyone outside and call 911 or the gas utility from there. Do not go back in to open windows or look for the source. If you smell gas, leave without touching light switches and call the utility from outside.

Carbon monoxide has no smell and no color. Early symptoms feel like flu without a fever: headache, dizziness, nausea, tiredness that eases when you leave the house.

  • Fit an alarm on every level of the house and outside each sleeping area. Test them monthly and replace them at the date printed on the back.
  • Burner flames should be blue and steady. Yellow, lifting or rolling flames need a technician.
  • Soot around the burner compartment, rust streaks on the vent pipe, or moisture on windows near a water heater can mean exhaust is not leaving the house.
  • Have a technician run a combustion analysis at the autumn check. It measures what the eye cannot.

Repair or replace?

Igniters, flame sensors, pressure switches, inducers and control boards are routine repairs on a furnace of any age. Replacement is worth pricing when the heat exchanger is cracked, when the furnace is past 15 to 20 years and needs a major part, or when repairs are arriving every winter. If the air conditioner is the same age, replacing both together saves a second installation. The installation guide covers what a careful replacement should include, and the maintenance calendar shows when to test the furnace so a failure does not find you in January.